BRTNM - ISOTON II DILUENT, 8546719 (20L)

  • MSDS: BRTNM
  • Manufacturer: COULTER ELECTRONICS INC
  • Product Name: ISOTON II DILUENT, 8546719 (20L)
  • National Stock Number: 6550-00F028529
Product Identification

Product ID:ISOTON II DILUENT, 8546719 (20L)
MSDS Date:01/27/1992
FSC:6550
NIIN:00F028529
MSDS Number: BRTNM

Responsible Party
COULTER ELECTRONICS INC
740 W 84TH ST
HIALEAH, FL 33014-3519
US

Emergency Phone: 305-822-8250

Info Phone: 305-822-8250

Cage: 5Z189

Contractor
CURTIN MATHESON SCIENTIFIC INC
AURORA, CO 80011-8154 US

Telephone: 303-340-2727

Cage: 4S896

Ingredients

ETHYLENE GLYCOL PHENYL ETHER, 2-PHENOXYETHANOL

CAS: 122-99-6

RTECS: KM0350000

Fraction By Weight: 0.3%


SODIUM FLUORIDE

CAS: 7681-49-4

RTECS: WB0350000

Fraction By Weight: 0.03%

OSHA PEL 2.5 MG/CUM

ACGIH TLV: 2.5 MG/CUM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


SODIUM CHLORIDE

CAS: 7647-14-5

RTECS: VZ4725000

Fraction By Weight: <1%


DISODIUM EDETATE; ACETIC ACID, (ETHYLENEDINITRILO)TETRA-,

CAS: 139-33-3

RTECS: AH4375000

Fraction By Weight: <1%


POTASSIUM CHLORIDE

CAS: 7447-40-7

RTECS: TS8050000

Fraction By Weight: <1%


SODIUM PHOSPHATE MONOBASIC, MONOSODIUM PHOSPHATE

CAS: 7558-80-7

RTECS: WA1900000

Fraction By Weight: <1%


SODIUM PHOSPHATE, DIBASIC, ANHYDROUS, DISODIUM PHOSPHATE

CAS: 7558-79-4

RTECS: WC4500000

Fraction By Weight: <1%

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: <1 GRAM (2 OR MORE LITERS
OF THIS PRODUCT) MAY CAUSE NAUSEA, VOMITING, ABDOMINAL PAIN,
STUPOR, WEAKNESS, TREMORS, RESPIRATORY & CARDIAC FAILURE. (SODIUM
FLUORIDE)
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INGESTION: 5-10 GRAMS (1 OR MORE LITERS OF THIS
PRODUCT) MAY CAUSE DEATH.

First Aid

First Aid:SKIN: FLUSH W/PLENTY OF WATER. INGESTION: GIVE VICTIM
APPROPRIATE DOSE OF EFFERVESCENT CALCIUM GLUCONATE (IN COPIOUS
AMOUNTS OF WATER OR MILK). OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:ANY EXTINGUISHING MEDIA SUITABLE FOR FIRE.
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:FLUSH W/WATER TO APPROVED OUTSIDE DRAINAGE.

Handling

Handling and Storage Precautions:DON'T REUSE. DISCARD EMPTY CONTAINER.
FOR IN VITRO DIAGNOSTIC USE. DON'T STACK OVER 4 HIGH. STORE AT ROOM
TEMP (20-25C).
Other Precautions:DON'T INGEST.

Exposure Controls

Respiratory Protection:NONE REQUIRED
Ventilation:NONE REQUIRED
Protective Gloves:NONE REQUIRED
Eye Protection:SAFETY GLASSES
Other Protective Equipment:LAB COATS
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:100C
Spec Gravity:1
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR LIQUID

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:HEAT
Hazardous Decomposition Products:POSSIBLE CHLORIDE SCALE

Disposal

Waste Disposal Methods:DISPOSE MUST COMPLY WITH FEDERAL, STATE & LOCAL
DISPOSAL OR DISCHARGE LAWS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.